Mfg Part Number: 213955-1 | Alternate P/N: 2139551 | NSN : 5950-00-385-8906 |
NIIN : 003858906 | CAGE Code : 54401 | Manufacturer: Transformer Engineers Co |
Item Name : Transformer Power | FSC : 5950 Coils and Transformers |
Thank you for using Industrials 3Sixty to secure your needed NSN components. Here, you can submit an Instant RFQ form for the part number 213955-1, which is listed under the NSN 5950-00-385-8906. This Transformer Power item, manufactured by Transformer Engineers Co, is listed with immediate availability on our website and may be purchased at any time. To begin, simply complete the RFQ form as found on this page with as much information as possible and hit submit. Once our account managers have received your request, they will immediately begin working on a customized solution and will return it to you within 15 minutes or less.
Our NSN catalog at Industrials 3Sixty is unparalleled, containing millions of ready-to-purchase items. Additionally, to aid in rapid discovery and procurement, we list every NSN component next to its respective cage code. For example, this part with the NSN 5950-00-385-8906 is associated with the CAGE Code 54401, which is assigned to Transformer Engineers Co. We are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited enterprise with a strict NO CHINA Sourcing policy, so you can purchase with the confidence that you will receive the highest quality components possible. Get started on the purchasing process today with the submission of an RFQ to experience the evolution of parts procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-385-8906 Item Description: Transformer Power | 5950 | 003858906 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
213955-1 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS8 ALL GROUPINGS8 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS0.250 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 0.6 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 8.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ALL VOLTAGES ARE STATED AS OPEN CIRCUIT; ALL CURRENTS ARE STATED AS RECTIFIED; 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARIES 5 & 6 ARE RATED 115VRMS |
THSD | THREAD SERIES DESIGNATOR | UNF ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 20 THREADED STUD |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote